LKC Technologies
Español
Español English Português 日本
  • Productos
    • For Humans
      • RETeval
      • UTAS mf/PERG
      • Sensor Strips
    • For Animals
      • RETevet
      • Request Demo
      • Order Supplies
  • Aplicaciones
    • Pruebas y ERG
      • Electroretinography (ERG)
      • Potencial evocado visual (PEV)
    • Condiciones clínicas
      • Retinopatía diabética
      • Glaucoma
      • Retinal Ischemic Diseases
      • Inherited Retinal Disorders
      • Miscellaneous
    • Aplicaciones en animales
  • Recursos
    • Case Studies
    • eBooks & Reports
    • Webinars
    • Articles
    • Investigación
    • Blog
    • Videos
    • Software
  • Acerca de LKC
    • Vision & Mission
    • Team
    • Clinical Advisors
    • testimonios
    • History
  • Contact
  • Eye Care Customers
  • VET Customers
  • Buy Sensor Strips

RETeval Device Reference Data

El RETeval® device includes built-in, age-adjusted reference data for human use. Physicians now have valuable input to aid in their interpretation and assessment of patient test results.

The reference intervals come from an ongoing clinical trial, the RETeval  All Comers Trial (REACT), sponsored by LKC Technologies (More on ClinicalTrials.gov). The study was conducted in five locations in three states utilizing an IRB approved protocol. All subjects completed informed consent forms.

Firmware version 2.8.0 and higher on the RETeval device includes reference intervals for most photopic tests, please refer to the user manual more details. Contact customer support for download information.

Note that the manual states that LKC Sensor Strip skin electrodes must be used to show the reference intervals, and electrode type “Sensor Strip” must be selected at the start of the test.

At a glance, the study included:

  • 522 subjects
  • Age range 2-93
  • 244 subjects (aged 4- 85) have been classified as having normal vision, based on the following criteria:
    • BCVA of 20/25 (0.1 logMAR) or better
    • optic nerve cupping < 50%
    • no glaucoma or retinal diseases
    • no prior intraocular surgery (excepting non-complicated cataract or refractive surgery performed more than one year before)
    • IOP ≤ 20 mmHg
    • no diabetes, and no diabetic retinopathy as determined by the ophthalmologist or optometrist
  • Dilated and undilated normal subjects
    • Some subjects (n=77) were tested after artificial dilation, while others were tested with natural pupils and constant Troland stimuli that compensate for pupil size (n=167). Dilated subjects who did not dilate to at least 6 mm were excluded.
  • Productos
    • RETeval
    • UTAS mf/PERG
    • Sensor Strips
    • RETevet
  • PRUEBAS DE ELECTROFISIOLOGÍA
    • Electroretinography (ERG)
    • ERG de campo completo (ffERG)
    • Patrón ERG (PERG)
    • ERG multifocal (mfERG)
    • Potencial evocado visual (PEV)
    • DIRECCIÓN2 Professional Drive, Suite 222
      Gaithersburg, MD 20879 USA
    • TELÉFONO+1 301 840 1992 (US & Canada)
      +358 40 8486625 (International)
    • DISTRIBUIDORES INTERNACIONALES
      • Distribuidores de Dispositivos Médicos
      • Distribuidores de Dispositivos Veterinarios
  • Follow LKC Technologies on LinkedIn
  • Follow LKC Technologies on Facebook
  • Subscribe to LKC Technologies on YouTube
  • Follow LKC Technologies on Instagram
cropped-cropped-LKC_logo_RGB_color_no_tagline_mini_400px.png
© 2025 LKC Technologies, Inc.
  • DECLARACIÓN DE ACCESIBILIDAD
  • TÉRMINOS Y CONDICIONES
  • CERTIFICACIONES
  • POLÍTICA DE PRIVACIDAD
  • CARRERAS